Title of article :
Field emission dark current of technical metallic electrodes
Author/Authors :
Le Pimpec، نويسنده , , F. and Ganter، نويسنده , , R. and Betemps، نويسنده , , R.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
10
From page :
7
To page :
16
Abstract :
In the framework of the Low Emittance Gun (LEG) project, high gradient acceleration of a low emittance electron beam will be necessary. In order to achieve this acceleration, a −500 kV, 250 ns FWHM, pulse will be applied between two electrodes. Those electrodes should sustain the pulsed field without arcing, must not outgas and must not emit electrons. Ion back bombardment, and dark current will be damaging to the electron source as well as for the low emittance beam. Electrodes of commercially available OFE copper, aluminium, stainless steel (SS), titanium and molybdenum were tested, following different procedures including plasma glow discharge cleaning.
Keywords :
DC Breakdown , Dark current , Plasma processing , High gradient , Field emission
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2007
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2205625