Title of article
CR-39 detector compared with Kodalpha film type (LR115) in terms of radon concentration
Author/Authors
Dwaikat، نويسنده , , Nidal and Safarini، نويسنده , , Ghassan and El-hasan، نويسنده , , Mousa and Iida، نويسنده , , Toshiyuki، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
3
From page
289
To page
291
Abstract
CR-39 detectors and Kodalpha film type (LR115) were compared in terms of radon radiation concentration. Thirteen CR-39 detectors with the same number of Kodalpha film type (LR115) were used in this study. The correlation factor between the radon concentrations, obtained by the two groups of detectors was found to be 0.99. Detector time efficiency (DTE) was calculated for both types of detectors. DTE of Kodalpha film is larger than that of CR-39 detector and this indicates that LR115 is more efficient and sensitive for radon radiation than CR-39 detector.
Keywords
CR-39 detector , Correlation factor , Kodalpha film type (LR115) , Detector time efficiency (DTE)
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2007