Title of article :
Testbeam results for the SiW electromagnetic calorimeter
Author/Authors :
Giannelli، نويسنده , , Michele Faucci، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Abstract :
A prototype of a highly granular SiW electromagnetic calorimeter composed of 6480 cells contained in a volume of 18×18×30 cm3 was installed and tested in 2006 at CERN by the CALICE collaboration. The analysis focuses on the resolution of the calorimeter to electromagnetic showers. The energy resolution was found to be 16.6 ± 0.1 / E ( GeV ) ⊕ 1.1 ± 0.1 ( % ) while the linearity was better than 1%. The analysis on embedded electronics showed no sign of signal induced by the shower.
Keywords :
CALICE , iLC , Electromagnetic calorimeter , Silicon detector , Electron reconstruction , Embedded electronics
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :