• Title of article

    TL and TSEE response of Wollastonite–Teflon composites in X-ray beams

  • Author/Authors

    Souza، نويسنده , , D.N. and Melo، نويسنده , , A.P. and Caldas، نويسنده , , L.V.E.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    4
  • From page
    338
  • To page
    341
  • Abstract
    Pellets of Wollastonite–Teflon composites were studied in relation to some TSEE and TL dosimetric characteristics: emission curves, calibration curves, and energy dependence (X-rays). The calibration curves of TSEE and TL response show a prominent and isolated dosimetric peak with maximum around 200 ∘ C that presents linearity between 1.5 and 6.0 Gy and a low energy dependence. TL and TSEE properties as glow peak positions and dose responses were determined and analyzed and the results showed that Wollastonite can be used in dosimetry, provided that energy dependence of its response is been properly taken into account.
  • Keywords
    THERMOLUMINESCENCE , Exoemission , Detectors , wollastonite
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2007
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2207477