Title of article :
A harmonic coil measurement system based on a dynamic signal acquisition device
Author/Authors :
Zhou، نويسنده , , J.X. and Li، نويسنده , , L. and Yin، نويسنده , , B.G and Deng، نويسنده , , C.D. and Kang، نويسنده , , W. and Chen، نويسنده , , Y. and Zhang، نويسنده , , Z. C. Fu، نويسنده , , S.N.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
5
From page :
549
To page :
553
Abstract :
A new harmonic coil measurement system based on a dynamic signal acquisition device has been successfully developed to check the field quality of the quadrupole magnet for the CSNS/RCS, which operates at the 25 Hz excitation cycle with a DC bias. It was designed to acquire multiple channels of data with a wide dynamic range of input signals, which are typically generated by a harmonic coil and an encoder. A dedicated algorithm was developed in LabView code to identify over specified intervals, synchronized to the coil’s rotation in the magnetic field. Through full integration of hardware and software, the traditional device (PDI 5025) is replaced successfully. This paper summarizes the characteristics of the system and presents the results of DC measurements.
Keywords :
DC and AC magnetic field measurements , Digital bucking , Harmonic coil , Dynamic signal acquisition device