Title of article :
A simple X-ray position detection system based on a MHSP
Author/Authors :
Natal da Luz، نويسنده , , H. and Veloso، نويسنده , , J.F.C.A. and dos Santos، نويسنده , , J.M.F. and Mir، نويسنده , , J.A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
4
From page :
1083
To page :
1086
Abstract :
A simple system for position detection based on a Micro-Hole and Strip Plate (MHSP) using a resistive charge division method was implemented. A thin resistive layer of about 100 Ω between each strip (top surface) and between each anode strip (bottom surface) allows us to obtain the actual position in both orthogonal directions. The readout electronics uses only two preamplifiers, a sum and a divider circuit to calculate the interaction point, in each dimension. For a detector filled with 1 atm of pure xenon, position resolutions of less than 300 μm (FWHM) were achieved using 5.9 keV X-rays, for a signal-to-noise ratio (SNR) of 30. For these conditions, a detector gain of about 104 and an energy resolution of about 15% were obtained.
Keywords :
Micro-hole and strip plate , 2D imaging , Resistive charge division , X-ray detectors , Analogue divider , Gas electron multiplier
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2007
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2207847
Link To Document :
بازگشت