Title of article :
Fast microwave detection system for coherent synchrotron radiation study at KEK: Accelerator test facility
Author/Authors :
Aryshev، نويسنده , , Juliano A. and Araki، نويسنده , , S. and Karataev، نويسنده , , P. and Naito، نويسنده , , T. and Terunuma، نويسنده , , N. and Urakawa، نويسنده , , J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
A fast room temperature microwave detection system based on the Schottky Barrier-diode detector was created at the KEK ATF (Accelerator Test Facility). It was tested using Coherent Synchrotron Radiation (CSR) generated by the 1.28 GeV electron beam in the damping ring. The speed performance of the detection system was checked by observing the CSR from a multi-bunch (2.8 ns bunch separation time) beam. The theoretical estimations of CSR power yield from an edge of bending magnet as well as new injection tuning method are presented. A very high sensitivity of CSR power yield to the longitudinal electron distribution in a bunch is discussed.
Keywords :
Fast detection systems , Coherent synchrotron radiation , Beam diagnostics
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A