Title of article :
Transmutation detectors
Author/Authors :
Viererbl، نويسنده , , L. and Lahodov?، نويسنده , , Z. and Klup?k، نويسنده , , V. and Sus، نويسنده , , F. and Ku?era، نويسنده , , J. and Kus، نويسنده , , P. and Marek، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
3
From page :
109
To page :
111
Abstract :
We have designed a new type of detectors, called transmutation detectors, which can be used primarily for neutron fluence measurement. The transmutation detector method differs from the commonly used activation detector method in evaluation of detector response after irradiation. Instead of radionuclide activity measurement using radiometric methods, the concentration of stable non-gaseous nuclides generated by transmutation in the detector is measured using analytical methods like mass spectrometry. Prospective elements and nuclear reactions for transmutation detectors are listed and initial experimental results are given. The transmutation detector method could be used primarily for long-term measurement of neutron fluence in fission nuclear reactors, but in principle it could be used for any type of radiation that can cause transmutation of nuclides in detectors. This method could also be used for measurement in accelerators or fusion reactors.
Keywords :
Transmutation detector , Activation method , Neutron fluence , Nuclear reactor , neutron detector
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2011
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2208038
Link To Document :
بازگشت