Title of article :
Resolution studies on 5 GeV electron tracks observed with triple-GEM and MediPix2/TimePix-readout
Author/Authors :
Bamberger، نويسنده , , A. and Desch، نويسنده , , K. and Renz، نويسنده , , U. and Titov، نويسنده , , Irina M. and Vlasov، نويسنده , , N. and Wienemann، نويسنده , , P. and Zwerger، نويسنده , , A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
This contribution investigates a prototype of a TPC readout with a highly pixelated CMOS ASIC, which is an option for charged particles tracking of the ILC. A triple GEM stack is joined with a TimePix and MediPix2 chip (pixel size of 55 × 55 μ m 2 ) and its readout properties are investigated with 5 GeV electrons. The spatial resolution of reconstructed cluster centers is determined as a function of the drift distance for different gases and stack configurations. Also the drift velocities are extracted. A single point resolution down to ≈ 25 μ m is achieved for small drift distances.
Keywords :
GEM , MPGD , Medipix , Timepix
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A