• Title of article

    Resolution studies on 5 GeV electron tracks observed with triple-GEM and MediPix2/TimePix-readout

  • Author/Authors

    Bamberger، نويسنده , , A. and Desch، نويسنده , , K. and Renz، نويسنده , , U. and Titov، نويسنده , , Irina M. and Vlasov، نويسنده , , N. and Wienemann، نويسنده , , P. and Zwerger، نويسنده , , A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    5
  • From page
    274
  • To page
    278
  • Abstract
    This contribution investigates a prototype of a TPC readout with a highly pixelated CMOS ASIC, which is an option for charged particles tracking of the ILC. A triple GEM stack is joined with a TimePix and MediPix2 chip (pixel size of 55 × 55 μ m 2 ) and its readout properties are investigated with 5 GeV electrons. The spatial resolution of reconstructed cluster centers is determined as a function of the drift distance for different gases and stack configurations. Also the drift velocities are extracted. A single point resolution down to ≈ 25 μ m is achieved for small drift distances.
  • Keywords
    GEM , MPGD , Medipix , Timepix
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2007
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number