• Title of article

    Signal and charge collection efficiency of a p-type STC 3D-detector irradiated to sLHC-fluences, read out with 40 MHz

  • Author/Authors

    Eckert، نويسنده , , S. and Ehrich، نويسنده , , T. and Jakobs، نويسنده , , K. and Kühn، نويسنده , , S. and Parzefall، نويسنده , , U. and Boscardin، نويسنده , , M. and Piemonte، نويسنده , , C. and Ronchin، نويسنده , , S.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    4
  • From page
    322
  • To page
    325
  • Abstract
    Using ATLAS SCT front-end electronics, we have built a 3D prototype detector module which was then irradiated to a fluence of 1 × 10 15 n eq / cm 2 . After irradiation, the module was tested with an IR-laser yielding relative CCE measurements with high spatial resolution. Position-sensitive measurements are required, as from simulation the STC 3D-detector geometry is expected to have low-field regions with lower CCE. We report on the performance of the irradiated 3D-module read out at 40 MHz, compare it to the unirradiated behaviour and draw conclusions about the feasibility of using such detectors for tracking at the sLHC.
  • Keywords
    sLHC fluences , n-in-p 3D detectors , Silicon microstrip detectors , Charge collection efficiency , Radiation hardness , Radiation damage