Title of article :
Development of a gaseous PMT with micro-pattern gas detectors
Author/Authors :
Sumiyoshi، نويسنده , , Takayuki and Tokanai، نويسنده , , Fuyuki and Sugiyama، نويسنده , , Hiroyuki and Okada، نويسنده , , Teruyuki and Ohishi، نويسنده , , Noboru and Ohmura، نويسنده , , Takayuki and Sakurai، نويسنده , , Hirohisa and Gunji، نويسنده , , Shuichi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
5
From page :
121
To page :
125
Abstract :
Gaseous photomultiplier tubes with micro-pattern gas detectors sensitive to visible light are under development. Long term stability of a bi-alkali photocathode is examined for more than 500 days. A micro-pattern gas detector of Kapton GEM is found to be incompatible with bi-alkali photocathode, while a glass capillary plate has no problem. A new production method for a Pyrex glass GEM has been developed. Some studies on ion-feedback suppression are presented.
Keywords :
Gaseous photomultiplier tube , Micro-pattern gas detector
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2011
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2208298