Author/Authors :
Alexopoulos، نويسنده , , T. and Burnens، نويسنده , , J. and de Oliveira، نويسنده , , R. and Glonti، نويسنده , , G. and Pizzirusso، نويسنده , , O. and Polychronakos، نويسنده , , V. and Sekhniaidze، نويسنده , , G. and Tsipolitis، نويسنده , , G. and Wotschack، نويسنده , , J.، نويسنده ,
Abstract :
We report on the design and performance of a spark-resistant bulk-micromegas chamber. The principle of this design lends itself to the construction of large-area muon chambers for the upgrade of the detectors at the Large Hadron Collider at CERN for luminosities in excess of 1034 cm−2 s−1 or other high-rate applications.
Keywords :
Micromegas , Spark protection , Resistive layer , Muon detector