• Title of article

    An electron density measurement using an analyzer based imaging system

  • Author/Authors

    Bewer، نويسنده , , Brian، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    3
  • From page
    197
  • To page
    199
  • Abstract
    Using a monochromatic X-ray beam from a synchrotron source the electron density of a homogeneous target was determined by measuring the refraction that occurs at the air–target interface for a known angle of incidence. The angle of deviation that these X-rays undergo at the transition between materials is micro-radian to submicro-radian in scale. Existing analyzer based imaging systems are designed to measure submicro-radian angle changes and commonly use monochromatic hard X-ray beams generated from synchrotron sources. A preliminary experiment using the analyzer based imaging apparatus at the Canadian Light Source Biomedical Imaging and Therapy beamline and a half cylinder shaped plastic target will be presented. By measuring the angle of deviation of the photon beam at several discrete angular positions of the target the electron density of the target material was determined.
  • Keywords
    Electronic density , X-ray refraction , Analyzer based imaging
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2011
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number