Title of article
Liquid metal leak detection for spallation neutron sources
Author/Authors
Thomsen، نويسنده , , K.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
7
From page
476
To page
482
Abstract
Short response times and the harsh radiation environment in liquid metal targets of spallation neutron sources pose stringent requirements and demanding boundary conditions for reliable liquid metal leak detection. For the PSI Megawatt pilot experiment (Megapie) liquid metal target two novel approaches have been pursued: a thermocouple-based leak detector and one employing impedance read out. During the whole operational life of the Megapie target satisfactory performance has been achieved. How these concepts can be further improved and easily be adapted to other installations based on the PSI experience will be described here.
Keywords
Liquid metal , Impedance sensor , Thermocouples , Radiation environment , Leak detector
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2008
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2209898
Link To Document