Title of article :
Improvements and problems of Bridgman–Stockbarger method for fabrication of TlBr single crystal detectors
Author/Authors :
Kozlov، نويسنده , , V. and Andersson، نويسنده , , H. and Gostilo، نويسنده , , V. and Kemell، نويسنده , , M. and Kostamo، نويسنده , , P. and Kouznetsov، نويسنده , , M.S. and Leskelن، نويسنده , , M. and Lipsanen، نويسنده , , H. and Lisitsky، نويسنده , , I.S. and Shorohov، نويسنده , , M. and Sipilن، نويسنده , , H.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
3
From page :
126
To page :
128
Abstract :
TlBr is a promising material for gamma-ray detectors; however, it has crystal quality problems originated from the crystal growth itself and further treatments during detector fabrication. The effect of technological improvements on crystal quality has been studied in this work. Low performance of studied detectors was shown to be associated with residual stress or/and small-angle grain boundaries in these crystals. Several crystals failed as detectors were proved to contain impurities.
Keywords :
X- and gamma-ray solid-state detectors , Growth from melts , Thallium bromide