Title of article :
Measurement and calculation of the neutron spectrum and gamma dosimetry of the fast neutron device at Xi’an Pulse Reactor
Author/Authors :
Liu، نويسنده , , Shu-Huan and Jiang، نويسنده , , Xin-Biao and Liu، نويسنده , , Nan-Nan and Zhu، نويسنده , , Guang-Ning and Li، نويسنده , , Da and Zhang، نويسنده , , Jihong and Yu، نويسنده , , Qing-Yu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
6
From page :
361
To page :
366
Abstract :
The neutron spectrum and neutron fluence of a fast neutron device at Xi’an Pulse Reactor were measured with multiple foil activation method and calculated with Monte Carlo technique in the paper. Thermo-luminescence detector (TLD) (7LiF(Mg,Ti)-1007M) is used to measure gamma dosimetry of the device. The experimental result proves that the goal of the design is achieved.
Keywords :
Gamma dosimetry , TLD , neutron spectrum , Fast neutron facility
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2008
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2210077
Link To Document :
بازگشت