• Title of article

    Optimization of a moderator-neutron guide system for diffractometers of beam line 7A of the IBR-2M reactor

  • Author/Authors

    Manoshin، نويسنده , , S.A. and Belushkin، نويسنده , , A.V. and Kulikov، نويسنده , , S.A. and Shabalin، نويسنده , , E.P. and Walther، نويسنده , , K. and Scheffzuek، نويسنده , , C. and Zhuravlev، نويسنده , , V.V.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    7
  • From page
    447
  • To page
    453
  • Abstract
    Neutron guides are widely used to transport the neutrons from the moderator to the sample. Due to the constructive features of the ring corridor of the fast pulsed reactor IBR-2, the minimal distance between the moderator and the guide entrance is around 6 m. The main goal of the paper is to optimize the neutron optical system between the moderator and the entrance of the new neutron guides. Using Monte Carlo simulations we calculate the possible best gain of the neutron flux density at the guide exit. After the described optimization process, the optimal system is obtained. The recommendations for construction of the new beam line are provided too. Similar technique and the proposed system could be easily adapted for another similar beam line at the neutron sources.
  • Keywords
    Neutron guide , Monte Carlo simulations , Beam line , optimization
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2009
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number