Title of article
TOPIX: The first prototype of pixel readout for PANDA experiment
Author/Authors
Calvo، نويسنده , , D. and De Remigis، نويسنده , , P. and Martoiu، نويسنده , , S. and Rivetti، نويسنده , , A. and Wheadon، نويسنده , , R.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
4
From page
96
To page
99
Abstract
The first prototype (TOPIX) of pixel readout has been designed and tested in a first attempt to develop a custom solution for the pixel detector of the PANDA experiment. A small circuit composed of 32 single pixel readout cells was implemented in a 130 nm CMOS process. Each cell is equipped with a preamplifier and a comparator circuit to measure the Time over Threshold (ToT). Several chips were characterized to check the uniformity of the preamplifier response and ToT signal. Total Ionizing Dose (TID) tests at different dose rate and displacement damage test were performed: the results of these measurements are reported in this paper.
Keywords
Readout , TOPIX , Radiation damage , pixel
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2008
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2210414
Link To Document