Title of article :
Plastic scintillator-based radiation detector for mobile radiation detection system against nuclear/radiological terrorism
Author/Authors :
Kwak، نويسنده , , Sung-Woo and Yoo، نويسنده , , Ho-Sik and Jang، نويسنده , , Sung Soon and Kim، نويسنده , , Jung Soo and Yoon، نويسنده , , Wan-Ki and Jun، نويسنده , , In Sub and Kim، نويسنده , , Kwang Hyun، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
3
From page :
161
To page :
163
Abstract :
Illicit trafficking of nuclear or radioactive materials has become a serious world wide problem. Due to operational constraints of radiation detection system for such nuclear security application, a radiation detector with large effective area is needed to maximize its sensitivity. This paper suggests a new method of using plastic scintillation detector as a cost-effective mobile radiation detection system. Monte Carlo simulation code, MCNPX, has been used to analyze spectral distribution available from the plastic detector and to derive algorithmic process with a view to discriminating targeted sources from ambient background radiation. Theoretical results in present work showed that the targeted sources which might be used for nuclear/radiological terrorism could be discriminated from Nationally Occurring Radioactive Material (NORM) or background.
Keywords :
Mobile radiation detection system , Nuclear/radiological terrorism , Nuclear security , Plastic scintillator
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2009
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2211205
Link To Document :
بازگشت