Title of article :
Design of input coupler for the superconducting cavity
Author/Authors :
Dhavale، نويسنده , , A.S. and Mittal، نويسنده , , K.C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
The present paper describes in detail the design of the co-axial coupler for the high beta (∼0.42) 700 MHz superconducting cavity. It also describes the Kroll–Yu method for the computation of external Q. A copper prototype of cavity and co-axial coupler is fabricated and the measurement of external Q is carried out. A measured cavity resonant frequency was 694.9 MHz. The external Q was measured for the axial coupler by changing the penetration depth from −74.53 to −29.53 mm the external Q was varied from ∼1.03×106 to 1.38×103. The experimental results and the computational results match well.
Keywords :
Kroll–Yu , sc , External Q
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A