• Title of article

    Annular flow analysis by tracers in drilling operations

  • Author/Authors

    Rodr??guez، نويسنده , , H.H and Ram??rez، نويسنده , , J.B and Vel?zquez، نويسنده , , D.C and Conejo، نويسنده , , A.N and Mart??nez، نويسنده , , J.A، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    10
  • From page
    287
  • To page
    296
  • Abstract
    A study of drilling fluid flow in the annular space and drill pipe by residence time distribution analysis using a tracer is presented. This is a new method which can be used to assess the rate of removal of cuttings during the drilling process. eld trials were conducted to evaluate the technical feasibility and potential application. The results are analyzed using the flow behavior, carrying capacity of the drilling fluid, and hole cleaning conditions. Analysis of tracer response indicates the presence of anomalous flow in both trials, characterized by two fluid volume fractions traveling with different velocities. The magnitude of these volume fractions is related directly to the carrying capacity of the drilling fluid (hence, the hole cleaning conditions) which is explained. The dispersion coefficient, as well as other distribution functions, is suggested to measure the overall behavior of fluid in a drill-hole. ethod is compared with empirical correlations employed in the industrial practice and potential advantages are demonstrated using tracers.
  • Keywords
    cuttings , Transport ratio , Hole cleanliness , Drilling rate , Tracers
  • Journal title
    Journal of Petroleum Science and Engineering
  • Serial Year
    2004
  • Journal title
    Journal of Petroleum Science and Engineering
  • Record number

    2215335