Title of article
Investigation on compliance rotation correction for compact tensile specimen in unloading compliance method
Author/Authors
Bao، نويسنده , , Chen and Cai، نويسنده , , Lixun، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
9
From page
144
To page
152
Abstract
The rotation correction method of unloading compliance for a compact tensile (CT) specimen in the current J-integral resistance curves or critical J-integral test standards was under suspicion by tracing to its source, and a new rotation correction method was proposed. The rotation center of the specimen is close to the crack tip, and the material constitutive relationship has little effect on the rotational radius R. If the formula for rotation correction recommended in current standards is used to measure the crack length of CT specimen, it will lead to larger error. A new formula with better accuracy for the crack length measurement of the CT specimen was presented.
Keywords
ductile fracture toughness , Unloading compliance , rotation correction , compact tensile specimen