Title of article :
Experimental analysis of particle concentration heterogeneity in a ventilated scale chamber
Author/Authors :
Jin، نويسنده , , Hanhui and Li، نويسنده , , Qingping and Chen، نويسنده , , Lihua and Fan، نويسنده , , Jianren and Lu، نويسنده , , Lin، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
8
From page :
4311
To page :
4318
Abstract :
The mixing processes of the aerosol particles from an outdoor environment in a ventilated scale chamber were experimentally studied. The particles were classified into five groups by size: 0.3–0.5 μm, 0.5–1.0 μm, 1.0–3.0 μm, 3.0–5.0 μm and 5.0–10.0 μm. The developing process for the concentration of each particle group was measured in different kinds of flow fields. sults show that the flow field configuration can effectively influence the dispersion time rate of the particles at certain positions. The increase in particle diameter can decrease the dispersion time rate. When the gas flow velocity is high, the particle dispersion time rate is independent of particle size; but when the gas flow velocity is low, particle size can significantly affect the particle dispersion time rate because the turbulent diffusion becomes important in the air and particle transport. The uniformity of the particle concentration for certain positions in steady state tends to be controlled by the inflow velocity, flow field configuration and the particle diameters.
Keywords :
indoor , fine particle , Concentration heterogeneity , Flow field , Mixing , experimental studies
Journal title :
Atmospheric Environment
Serial Year :
2009
Journal title :
Atmospheric Environment
Record number :
2235383
Link To Document :
بازگشت