Title of article :
Emission and profile characteristic of polycyclic aromatic hydrocarbons in PM2.5 and PM10 from stationary sources based on dilution sampling
Author/Authors :
Kong، نويسنده , , Shaofei and Ji، نويسنده , , Yaqin and Li، نويسنده , , Zhiyong and Lu، نويسنده , , Xiao-Bing and Bai، نويسنده , , Zhipeng، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
11
From page :
155
To page :
165
Abstract :
The mass concentrations and profile characteristic for 18 kinds of polycyclic aromatic hydrocarbons (PAHs) in PM2.5 and PM10 from stack gases for six types of stationary sources in Shandong Province, China were studied by a dilution sampling system and GC–MS analysis method from February to March in 2010. The mass concentrations of PM2.5 and PM10 from the six types of stationary sources varied in 8.2–79.4 mg m−3 and 23.3–156.7 mg m−3, respectively. The total mass concentrations of analyzed PAHs in PM2.5 and PM10 were in the ranges of 0.40–94.35 μg m−3 and 9.16–122.91 μg m−3. The most toxic ashes were from sinter and coke oven for both PM2.5 and PM10 with high carcinogenic PAHs concentrations. BbF, Phe, NaP, BghiP, Pyr, BaP and BeP were abundant which was different from formers and one of the key reasons may be the differences of sampling methods. Diversities in PAHs compositions existed between fly ashes within PM2.5 and PM10 fractions for coke oven according to coefficient of divergence (CD) values. PAHs profiles for PM10 emitted from coke oven were different from those of other stationary sources (with CD values higher than 0.35) and for PM2.5, it was the same for sinter (with most CD values close to 0.30). There existed similar PAHs markers for fine particles emitted from stationary sources excepted for the sinter. For PM10, PAHs markers were primary 3-ring PAHs except for the coke oven with BbF, IND and BghiP as its signatures. Diagnostic ratios of BaA/(BaA + Chr), Flu/(Flu + Pyr), BaP/(BaP + BeP), BeP/BghiP and IND/(IND + BghiP) could be not well distinguished for the six types of stationary sources with the maximum/minimum ratios lower than 2 for both PM2.5 and PM10 of fly ashes which should be not used for source identification studies. The mass concentrations and source profiles of PAHs should be updated timely for size-differentiated fly ashes from various stationary sources by dilution sampling method.
Keywords :
Polycyclic aromatic hydrocarbons , Profile , PM10 , Dilution sampling , Stationary sources , PM2.5
Journal title :
Atmospheric Environment
Serial Year :
2013
Journal title :
Atmospheric Environment
Record number :
2241377
Link To Document :
بازگشت