• Title of article

    Investigation of formaldehyde and acetaldehyde sampling rate and ozone interference for passive deployment of Waters Sep-Pak XPoSure samplers

  • Author/Authors

    Mullen، نويسنده , , Nasim A. and Russell، نويسنده , , Marion L. and Lunden، نويسنده , , Melissa M. and Singer، نويسنده , , Brett C.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    6
  • From page
    184
  • To page
    189
  • Abstract
    This study investigated formaldehyde and acetaldehyde passive sampling rates and ozone interference for the DNPH-based Waters Sep-Pak XPoSure sampler. Previous studies have shown that ozone interferes with active sampling by this cartridge. Our study included one laboratory and six field experiments conducted in Northern California homes. Passive sampling rates of 1.10 ± 0.09 and 0.86 ± 0.10 mL min−1 determined for formaldehyde and acetaldehyde are lower than previously reported. In a controlled laboratory experiment there were small, statistically insignificant impacts of subsequent ozone exposure on formaldehyde and acetaldehyde mass passively collected on the samplers. This sampler is inexpensive, easy to deploy and to transport by mail, and has a high sampling capacity when used passively; it is suitable for a wide-range of monitoring applications. However, the passive sampling rate remains in question given the internally consistent, but different results obtained in our study and the previous study.
  • Keywords
    aldehyde , exposure , Indoor air quality , Passive sampler , Residential
  • Journal title
    Atmospheric Environment
  • Serial Year
    2013
  • Journal title
    Atmospheric Environment
  • Record number