Title of article :
A direct method of measuring gaseous emissions from naturally ventilated dairy barns
Author/Authors :
Joo، نويسنده , , H.S. and Ndegwa، نويسنده , , P.M. and Heber، نويسنده , , A.J. and Bogan، نويسنده , , B.W. and Ni، نويسنده , , J.-Q. and Cortus، نويسنده , , E.L. and Ramirez-Dorronsoro، نويسنده , , J.C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
Air pollutant emission rates from mechanically ventilated (MV) dairy barns are determined from the product of the differences in concentrations of pollutants in air at the inlet and exhaust points and the corresponding ventilation rates. In contrast to well defined entry and exit points in MV barns, large area air inlets or outlets characterize naturally ventilated (NV) freestall dairy barns. Complicating this scenario even more, pertinent airflow characteristics (velocity and direction) necessary for determining ventilation rates vary continuously, both temporally and spatially. This paper describes implementation of a direct method, generally equivalent to the approach used for MV barns, for determining air emission rates of NV barns. Ultrasonic anemometers (sonics) located at salient points in the barn openings mapped air inflow and outflow velocities necessary to calculate ventilation rates. Pollutant concentrations in the air entering or leaving the barn during a given period were measured at sampling points located next to the anemometers. The air inflow rates were, in general, higher than the air outflow rates from the barns, but diurnal profiles were similar. The observed ventilation characteristics were consistent with prevailing wind directions. Air inflows were observed predominantly at windward openings of the barn, while the outflows were mainly at the barnʹs leeward openings. Results indicated that either: (i) the average of the air inflow and outflow rates (averaging approach), or (ii) the air inflow rates (inflow-only approach) were credible representations of ventilation rates. Results also revealed use of an on-site weather station and one sonic mounted in the middle of each wall of the barn as a possible approach for determining barn ventilation rates. The suggested use of ventilation rates for interpolating missing concentrations from intermittent gas measurements could potentially increase the integrity of emission rates at significantly lower capital investment and operational costs.
Keywords :
Emission rates , Area inlets , Area outlets , Ultrasonic anemometer , Indirect ventilation rates , Direct ventilation rates
Journal title :
Atmospheric Environment
Journal title :
Atmospheric Environment