Title of article :
Quantitative 3D petrography using x-ray tomography: Application to Bishop Tuff pumice clasts
Author/Authors :
Gualda، نويسنده , , Guilherme A.R. and Rivers، نويسنده , , Mark، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
15
From page :
48
To page :
62
Abstract :
Textures are traditionally studied using the petrographic microscope, which limits observations to 2D sections of 3D objects. Given the difficulty in retrieving information on shapes, sizes and spatial distribution of objects in 3D from random sections, a method that can yield observations in 3D is highly desirable. tomography yields a 3D map of the linear X-ray attenuation coefficient, which is a function of the atomic number and density of the material, and the X-ray energy used. Based on the compositional contrasts between different phases, various phases can be identified in a rock. clasts, characterized by isolated crystals surrounded by a low-density matrix, are ideal for the application of this technique. We present our first results obtained using X-ray tomography for pumice clasts from the Bishop Tuff. Samples studied are from units F7 and F8, and are representative of the variability in density and crystal contents observed in the early erupted Bishop Tuff. ere collected on the GeoSoilEnvironCARS beamline at the Advanced Photon Source, Argonne National Laboratory, using a 22 keV monochromatic X-ray beam. Image analysis was performed using the software Blob3D. ness contrasts in the resulting images allow the separation of magnetite, sanidine, quartz (including minor plagioclase), glass and vesicles. Crystals smaller than 5 voxels in diameter cannot be quantified properly, mostly due to noise in the images. This constrains the spatial resolution of the resulting images, such that there is a trade-off between sample size and spatial resolution. We employed two runs with samples of varying sizes (5 and 10 mm) to obtain adequate resolution (voxel sizes, ca. 8 and 17 μm). e previously studied quartz size distributions in Bishop pumice clasts using a crushing, sieving, and winnowing procedure. The agreement between our new and previous results is excellent. Quartz size distributions obtained using the tomography data are concave-upward on (population density vs. size plots) and resemble the size distributions for all quartz crystals (including both whole crystals and fragments). These size distributions were probably generated by fragmentation, through which large crystals were converted in a larger number of small crystals; petrographic observations suggest fragmentation occurred mostly under magmatic conditions. Sanidine size distributions are similar to those observed for quartz. Magnetite size distributions are typically linear, indicating a simple magmatic history, in contrast with the tektosilicates.
Keywords :
crystal size distribution , textures , X-ray tomography , Rhyolite , Bishop Tuff
Journal title :
Journal of Volcanology and Geothermal Research
Serial Year :
2006
Journal title :
Journal of Volcanology and Geothermal Research
Record number :
2244877
Link To Document :
بازگشت