Title of article :
Applicability of Ultrasonic Testing for the Determination of Volume Fraction of Particulates in Alumina-Reinforced Aluminum Matrix Composites
Author/Authors :
Fang، نويسنده , , C.-K. and Fang، نويسنده , , R.L. and Weng، نويسنده , , W.P. and Chuang، نويسنده , , T.H.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Abstract :
An ultrasonic testing technique was employed to determine the volume fraction of alumina particulate reinforcement in 6061 aluminum matrix composites. This study was performed on various composites with Al2O3 nominal volume fractions of 10, 15, and 20%. For comparison, other techniques were employed as well, including the Archimedes method, metallographic image analysis, X-ray diffraction, and acid dissolution. Observations indicated that ultrasonic testing and acid dissolution methods are more reliable than the other techniques, while ultrasonic testing is faster than the acid dissolution method.
Journal title :
Materials Characterization
Journal title :
Materials Characterization