Title of article :
Fatigue behaviour of boron free and boron containing heat treated Ti-13Zr-13Nb alloy for biomedical applications
Author/Authors :
Majumdar، نويسنده , , P. and Singh، نويسنده , , S.B. and Chakraborty، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
6
From page :
1394
To page :
1399
Abstract :
Fatigue behaviour of heat treated Ti-13Zr-13Nb (TZN) and Ti-13Zr-13Nb-0.5B (TZNB) alloys for biomedical implants has been investigated by rotating bending test. It was found that fatigue strength of TZN and TZNB alloys is comparable with that of conventionally used biomedical titanium alloys. Addition of boron to TZN alloy deteriorates fatigue strength.
Keywords :
Titanium alloy , microstructure , Fatigue , SEM