Title of article :
Studies on impeller type, impeller speed and air flow rate in an industrial scale flotation cell. Part 3: Effect on superficial gas velocity
Author/Authors :
Gorain، نويسنده , , B.K and Franzidis، نويسنده , , J.-P. and Manlapig، نويسنده , , E.V.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
16
From page :
639
To page :
654
Abstract :
Superficial gas velocity was measured at different locations in a 2.8 m3 portable industrial scale sub-aeration flotation cell, treating zinc cleaner feed at Hellyer Concentrator in Tasmania, Australia. The cell was fitted in turn with four different impeller-stator systems, and operated over a range of air flow rates and impeller speeds. Superficial gas velocity values ranged from 0.29 cm/sec to 6.4 cm/sec at the air flow rates employed. The distribution of air in the cell was very dependent on the impeller type, as well as on the operating conditions in the cell. For a well dispersed condition, the value of superficial gas velocity was uniform at different locations, whereas for flooding conditions the superficial gas velocity was very high near to the impeller and much lower away from the impeller.
Keywords :
Agitation , froth flotation , Flotation bubbles
Journal title :
Minerals Engineering
Serial Year :
1996
Journal title :
Minerals Engineering
Record number :
2272632
Link To Document :
بازگشت