Title of article :
A feed-line aerated flotation column part 2: Modelling and scale-up
Author/Authors :
Xu، نويسنده , , M. and Quinn، نويسنده , , P. and Stratton-Crawley، نويسنده , , R.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
12
From page :
655
To page :
666
Abstract :
For column scale-up, two parameters must be known: mineral rate constant and solids vessel dispersion number. Rate constants for all minerals can be measured from two modes of column operation, i.e., batch and continuous. Vessel dispersion number of solids particles can be readily predicted using available correlations and is related to column size, particle size and operating conditions. onstants measured from the two modes of column operation are described and compared. It was found that the rate constant obtained from batch column was less than that obtained from continuous operation. The impact of this difference upon column scale-up is investigated.
Keywords :
Modelling , column flotation , flotation kinetics
Journal title :
Minerals Engineering
Serial Year :
1996
Journal title :
Minerals Engineering
Record number :
2272634
Link To Document :
بازگشت