Title of article :
Experimental investigation into the application of a magnetic cyclone for dense medium separation
Author/Authors :
Svoboda، نويسنده , , J and Coetzee، نويسنده , , C and Campbell، نويسنده , , Q.P، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
9
From page :
501
To page :
509
Abstract :
The density differential between the overflow and underflow streams is one of the critical measurable parameters in the operation of dense medium cyclones. Our investigation of the application of a magnetic cyclone to dense medium separation showed that by a judicious positioning of a solenoid magnet along the axis of the cyclone, and by adjusting the strength of the magnetic field, it is possible to control the density differential in the cyclone. It is also possible to influence the cut-point density and the sharpness of the Tromp curve and the selectivity of separation. Typically, it was possible to vary the density differential in a wide range from −0.1 to 0.8 g/cm3. The cut-point density was controlled between 2.8 and 3.2 g/cm3 for 270D ferrosilicon, at a feed density of 2.35 g/cm3, and between 3.1 and 3.4 g/cm3 for Cyclone 60, at a feed density of 2.45 g/cm3. The Ep of separation was observed to decrease from 0.05 to 0.01 by the application of the magnetic field, accompanied by reduced cut-point density.
Keywords :
Magnetic separation , hydrocyclones , dense medium separation
Journal title :
Minerals Engineering
Serial Year :
1998
Journal title :
Minerals Engineering
Record number :
2273210
Link To Document :
بازگشت