• Title of article

    Hydrocyclones in dewatering circuits

  • Author/Authors

    Firth، نويسنده , , B.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    6
  • From page
    115
  • To page
    120
  • Abstract
    When hydrocyclones are used in dewatering circuits it is important to know the potential impact of trying to balance the flow of liquid to the overflow and underflow streams and the size distribution of the solids in these respective streams. The diameters of the vortex finder and spigot play important roles in this balance but neglecting the effect of the feed size distribution could also severely impact the final outcome. This is particularly the case where the transport of coarse particles through the spigot becomes a significant factor. aper presents a model which accounts for these effects and examines its capability with a data set of over 40 experimental trials with a 225 mm cyclone with a broad range of operating conditions (solids concentration, vortex finder and spigot diameters and flow rates). The model’s capability was then subsequently subjected to a further examination by altering the feed size distribution so that it contained a significantly greater amount of material in the size range near the separation size (0.090–0.200 mm). Good results were obtained in both cases.
  • Keywords
    Modelling , Classification , Dewatering , hydrocyclones
  • Journal title
    Minerals Engineering
  • Serial Year
    2003
  • Journal title
    Minerals Engineering
  • Record number