Title of article :
Electrocoagulation as a remediation tool for wastewaters containing arsenic
Author/Authors :
Hansen، نويسنده , , Henrik K. and Nٌْez، نويسنده , , Patricio and Grandon، نويسنده , , Rodrigo، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
This work shows results of electrocoagulation of solutions containing arsenic. The continuous flow treatment consisted of an electrocoagulation reactor with two parallel iron plates and a sedimentation basin.
sults showed that the electrocoagulation process of a 100 mg/L As(V) solution could decrease the arsenic concentration to less than 2 mg/L in the effluent with a current density of 1.2 A/dm2 and a residence time of around 9 min. Liquid flow was 3 L/h, and the DC current was reversed each 2 min.
sing the current density from 0.8 to 1.2 A/dm2, the Fe3+ and OH− dosages increase too, and thereby favouring the As removal. On the other hand, it seems that increasing the current density beyond a maximum value, the electrocoagulation process would not improve further. This could probably be explained by passivation of the anode.
Keywords :
Oxidation , Reclamation , Flocculation , Environmental , Waste processing
Journal title :
Minerals Engineering
Journal title :
Minerals Engineering