Author/Authors :
King، نويسنده , , Junfu and Li، نويسنده , , Qiang and Wang، نويسنده , , Alex and He، نويسنده , , Cathy and Zhou، نويسنده , , Joey and Deng، نويسنده , , Henry and Xu، نويسنده , , Ray، نويسنده ,
Abstract :
It is well-known that lab tests on wear-rate of grinding media cannot precisely represent its industrial performance due to complex grinding conditions. Nevertheless the lab data provides reference to the industrial data. Therefore, a reproducible test method on wear-rate in lab is necessary.
viding detailed data, this paper challenges the traditional wear-rate testing methods. Two commonly used methods on wear-rate test, self-wear in water and grinding with mineral slurry, are respectively employed. However, obvious fluctuation of wear-rate/time curves indicates neither of the two normal methods is reliable.
aper introduces a wear-rate testing method on lab scale which combines self-wear in water and grinding with mineral slurry. By this method, some repeatable wear-rate/time curves are displayed after a few hours. The mechanism will be discussed in detail in this paper.