Title of article :
The optical calcium frequency standards of PTB and NIST
Author/Authors :
Sterr، نويسنده , , U. and Degenhardt، نويسنده , , C. and Stoehr، نويسنده , , H. and Lisdat، نويسنده , , Ch. and Schnatz، نويسنده , , H. and Helmcke، نويسنده , , J. and Riehle، نويسنده , , F. and Wilpers، نويسنده , , G. and Oates، نويسنده , , Ch. and Hollberg، نويسنده , , L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
11
From page :
845
To page :
855
Abstract :
We describe the current status of the Ca optical frequency standards with laser-cooled neutral atoms realized in two different laboratories for the purpose of developing a possible future optical atomic clock. Frequency measurements performed at the Physikalisch-Technische Bundesanstalt (PTB) and the National Institute of Standards and Technology (NIST) make the frequency of the clock transition of 40Ca one of the best known optical frequencies (relative uncertainty 1.2 × 10 −14 ) and the measurements of this frequency in both laboratories agree to well within their respective uncertainties. Prospects for improvement by orders of magnitude in the relative uncertainty of the standard look feasible. To cite this article: U. Sterr et al., C. R. Physique 5 (2004).
Keywords :
Laser spectroscopy , Atomic clock , Optical frequency standard , ةtalons de fréquence optique , Horloge atomique , Spectroscopie laser