Title of article :
The development and testing of glaze materials for application to the fit surface of dental ceramic restorations
Author/Authors :
Cattell، نويسنده , , Michael J. and Chadwick، نويسنده , , Thomas C. and Knowles، نويسنده , , Jonathan C. and Clarke، نويسنده , , Richard L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
Objectives
ms of the study were to develop and test overglaze materials for application to the fit surface of dental ceramic restorations, which could be etched and adhesively bonded and increase the flexural strength of the ceramic substrate.
s
glaze materials were developed using commercial glass powders (P25 and P54, Pemco, Canada). P25 (90 wt%) was mixed with P54 (10 wt%) to produce (P25/P54). P54 (90 wt%) was mixed with P25 (10 wt%) to produce (P54/P25). P25 (90 wt%) was mixed with 10 wt% of an experimental glass powder (P25/frit). Eighty-two disc specimens (14 mm × 2 mm) were produced by heat pressing a leucite glass–ceramic and were sandblasted with 50 μm glass beads. Group 1 control specimens (10) were sandblasted. Groups 2–4 (10 per group) were coated using P25/frit (Group 2), P25/P54 (Group 3) and P54/P25 (Group 4) overglazes before sintering. Groups 1–4 were etched for 2 min using 9.5% HF (Gresco, USA). Composite cylinders (Marathon® v, Den-Mat) were light cured and bonded to the glazed and prepared disc surfaces and groups water stored for 8 days. Groups were tested using shear bond strength (SBS) testing at 0.5 mm/min. Disc specimens (42) were tested using the biaxial flexural strength (BFS) test at a crosshead speed of 0.15 mm/min. Group 1 was tested as sandblasted (21) and Group 2 (21) after coating the tensile surface with P25/frit. Xrd, Eds and Sem analyzes were carried out.
s
BS (MPa ± S.D.) were: Group 1: 10.7 ± 2.1; Group 2: 9.8 ± 1.9; Group 3: 1.8 ± 1.0 and Group 4: 2.6 ± 1.7. Groups 1 and 2 were statistically different to Groups 3 and 4 (p < 0.001), but there was no difference between Groups 1 and 2 and 3 and 4 (p > 0.05). The mean BFS (MPa ± S.D.) of the overglazed Group 2 (200.2 ± 22.9) was statistically different (p < 0.001) to Group 1 (150.4 ± 14.3).
icance
5/frit overglaze significantly (p < 0.001) increased the biaxial flexural strength of the leucite glass–ceramic substrate and produced comparable shear bond strengths to an etched and bonded control. The application of etched overglaze materials to dental glass–ceramic and ceramic substrates may be useful in adhesive dentistry.
Keywords :
ceramics , Leucite , Glaze , Microscopy , X-ray diffraction