Title of article
Measure of microhardness, fracture toughness and flexural strength of N-vinylcaprolactam (NVC)-containing glass-ionomer dental cements
Author/Authors
Moshaverinia، نويسنده , , Alireza and Brantley، نويسنده , , William A. and Chee، نويسنده , , Winston W.L. and Rohpour، نويسنده , , Nima and Ansari، نويسنده , , Sahar and Zheng، نويسنده , , Fengyuan and Heshmati، نويسنده , , Reza H. and Darr، نويسنده , , Jawwad A. and Schricker، نويسنده , , Scott R. and Rehman، نويسنده , , Ihtesham U. Rehman، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
7
From page
1137
To page
1143
Abstract
Objectives
estigate the effects of N-vinylcaprolactam (NVC)-containing terpolymers on the fracture toughness, microhardness, and flexural strength of conventional glass-ionomer cements (GIC).
s
rpolymer of acrylic acid (AA)–itaconic acid (IA)–N-vinylcaprolactam (NVC) with 8:1:1 (AA:IA:NVC) molar ratio was synthesized by free radical polymerization and characterized using 1H NMR and FTIR. Experimental GIC samples were made from a 50% solution of the synthesized terpolymer with Fuji IX powder in a 3.6:1 P/L ratio. Specimens were mixed and fabricated at room temperature. Plane strain fracture toughness (KIc) was measured in accordance with ASTM Standard 399-05. Vickers hardness was determined using a microhardness tester. Flexural strength was measured using samples with dimensions of 2 mm × 2 mm × 20 mm. For all mechanical property tests, specimens were first conditioned in distilled water at 37 °C for 1 day or 1 week. Fracture toughness and flexural strength tests were conducted on a screw-driven universal testing machine using a crosshead speed of 0.5 mm/min. Values of mechanical properties for the experimental GIC were compared with the control group (Fuji IX GIC), using one-way ANOVA and the Tukey multiple range test at α = 0.05.
s
C-modified GIC exhibited significantly higher fracture toughness compared to the commercially available Fuji IX GIC, along with higher mean values of flexural strength and Vickers hardness, which were not significantly different.
icance
concluded that NVC-containing polymers are capable of enhancing clinically relevant properties for GICs. This new modified glass-ionomer is a promising restorative dental material.
Keywords
N-vinylcaprolactam (NVC)-containing glass-ionomer , Microhardness , Fracture toughness and flexural strength , Dental cements
Journal title
Dental Materials
Serial Year
2010
Journal title
Dental Materials
Record number
2317567
Link To Document