Title of article
Biomimetic dentin desensitizer based on nano-structured bioactive glass
Author/Authors
Mitchell، نويسنده , , John C. and Musanje، نويسنده , , Lawrence and Ferracane، نويسنده , , Jack L.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
8
From page
386
To page
393
Abstract
Objectives
tudy evaluated the ability of a novel sol–gel bioactive glass, in conjunction with appropriate carrier vehicles, to reduce dentinal fluid flow, with an eye toward reducing dentinal hypersensitivity.
s
ments were conducted to measure the reduction in tubule fluid flow after treatment of cut tooth surfaces with sol–gel bioactive glass particles in several carrier vehicles. Surfaces were also examined after exposure to brushing and acidic solutions. A non-bioactive particulate glass was compared.
s
r occlusion produced by the bioactive glass was observed via SEM and a sustained reduction in hydrodynamic conductance was measured after exposure to various fluids and brushing.
sions
ew material may be used with the tested carriers to significantly and durably reduce tubule fluid flow, ultimately resulting in reduced dentinal hypersensitivity.
Keywords
Dentin desensitizer , Dental hypersensitivity , Hydraulic conductance , Bioactive glass
Journal title
Dental Materials
Serial Year
2011
Journal title
Dental Materials
Record number
2317637
Link To Document