• Title of article

    Polymerization kinetics and reactivity of alternative initiators systems for use in light-activated dental resins

  • Author/Authors

    Ely، نويسنده , , Marie-Caroline and Schneider، نويسنده , , Luis Felipe J. and Ogliari، نويسنده , , Fabrيcio A. and Schmitt، نويسنده , , Carla C. and Corrêa، نويسنده , , Ivo C. and Lima، نويسنده , , Giana da S. and Samuel، نويسنده , , Susana M.W. and Piva، نويسنده , , Evandro، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    8
  • From page
    1199
  • To page
    1206
  • Abstract
    Objectives rpose of this study was to evaluate the reactivity and polymerization kinetics behavior of a model dental adhesive resin with water-soluble initiator systems. s mer blend based on Bis-GMA, TEGDMA and HEMA was used as a model dental adhesive resin, which was polymerized using a thioxanthone type (QTX) as a photoinitiator. Binary and ternary photoinitiator systems were formulated using 1 mol% of each initiator. The co-initiators used in this study were ethyl 4-dimethylaminobenzoate (EDAB), diphenyliodonium hexafluorophosphate (DPIHFP), 1,3-diethyl-2-thiobarbituric acid (BARB), p-toluenesulfinic acid and sodium salt hydrate (SULF). Absorption spectra of the initiators were measured using a UV–Vis spectrophotometer, and the photon absorption energy (PAE) was calculated. The binary system camphorquinone (CQ)/amine was used as a reference group (control). Twelve groups were tested in triplicate. Fourier-transform infrared spectroscopy (FTIR) was used to investigate the polymerization reaction during the photoactivation period to obtain the degree of conversion (DC) and maximum polymerization rate (Rpmax) profile of the model resin. s analyzed absorption profiles, the absorption spectrum of QTX is almost entirely localized in the UV region, whereas that of CQ is in the visible range. With respect to binary systems, CQ + EDAB exhibited higher DC and R p max values. In formulations that contained ternary initiator systems, the group CQ + QTX + EDAB was the only one of the investigated experimental groups that exhibited an R p max value greater than that of CQ + EDAB. The groups QTX + EDAB + DPIHFP and QTX + DPIHFP + SULF exhibited values similar to those of CQ + EDAB with respect to the final DC; however, they also exhibited lower reactivity. icance soluble initiator systems should be considered as alternatives to the widely used CQ/amine system in dentin adhesive formulations.
  • Keywords
    Dental adhesive , Light polymerization of dental adhesives , Phase separation , Fourier transform infrared spectroscopy , Water-Soluble , Thioxanthone , Spectrophotometry
  • Journal title
    Dental Materials
  • Serial Year
    2012
  • Journal title
    Dental Materials
  • Record number

    2318166