Title of article :
Dimensional Stability of Two Polyvinyl Siloxane Impression Materials in Different Time Intervals
Author/Authors :
اعلايي، شيما نويسنده Department of Prosthodontics, School of Dentistry, Qazvin University of Medical Sciences, Qazvin, Iran Aalaei , Shima , رضايي، امين نويسنده Department of Prosthodontics, School of Dentistry, Qazvin University of Medical Sciences, Qazvin, Iran Rezaei Adli , Amin , منصورالي، محمدرضا نويسنده General dentist, School of Dentisty, Tehran university of Medical Sciences,Tehran, Iran Mansoorali, Mohammad Reza , غلامي، فاطمه نويسنده ,
Issue Information :
فصلنامه با شماره پیاپی 6 سال 2015
Abstract :
Statement of the Problem: Dental prosthesis is usually made indirectly; therefore
dimensional stability of the impression material is very important. Every
few years, new impression materials with different manufacturers’ claims
regarding their better properties are introduced to the dental markets which
require more research to evaluate their true dimensional changes.
Objectives: The aim of this study was to evaluate dimensional stability of additional
silicone impressionmaterial (Panasil® and Affinis®) in different time
intervals.
Materials and Methods: In this experimental study, using two additional silicones
(Panasil® and Affinis®), we made sixty impressions of standard die
in similar conditions of 23 °C and 59% relative humidity by a special tray.
The die included three horizontal and two vertical lines that were parallel. The
vertical line crossed the horizontal ones at a point that served as reference for
measurement.
All impressions were poured with high strength dental stone. The dimensions
were measured by stereo-microscope by two examiners in three interval storage
times (1, 24 and 168 hours).The data were statistically analyzed using t-test
and ANOVA.
Results: All of the stone casts were larger than the standard die. Dimensional
changes of Panasil and Affinis were 0.07%, 0.24%, 0.27% and 0.02%, 0.07%,
0.16% after 1, 24 and 168 hours, respectively. Dimensional change for two
impression materials wasn’t significant in the interval time, expect for Panasilafter
one week (p = 0.004).
Conclusions: According to the limitations of this study, Affinis impressions
were dimensionally more stable than Panasil ones, but it was not significant.
Dimensional change of Panasil impression showed a statistically significant
difference after one week. Dimensional changes of both impression materials
were based on ADA standard limitation in all time intervals ( < 0.5%); therefore,
dimensional stability of this impression was accepted at least until one week.
Journal title :
Journal of Dental Biomaterials
Journal title :
Journal of Dental Biomaterials