• Title of article

    The inaccuracy of conventional one-dimensional parallel thermal resistance circuit model for two-dimensional composite walls

  • Author/Authors

    Wong، نويسنده , , King-Leung and Hsien، نويسنده , , Tsung-Lieh and Hsiao، نويسنده , , Ming-Chien and Chen، نويسنده , , Wen-Lih and Lin، نويسنده , , Ku-Chin، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    9
  • From page
    2554
  • To page
    2562
  • Abstract
    This investigation is to show that two-dimensional steady state heat transfer problems of composite walls should not be solved by the conventionally one-dimensional parallel thermal resistance circuits (PTRC) model because the interface temperatures are not unique. Thus PTRC model cannot be used like its conventional recognized analogy, parallel electrical resistance circuits (PERC) model which has the unique node electric voltage. Two typical composite wall examples, solved by CFD software, are used to demonstrate the incorrectness. The numerical results are compared with those obtained by PTRC model, and very large differences are observed between their results. This proves that the application of conventional heat transfer PTRC model to two-dimensional composite walls, introduced in most heat transfer text book, is totally incorrect. An alternative one-dimensional separately series thermal resistance circuit (SSTRC) model is proposed and applied to the two-dimensional composite walls with isothermal boundaries. Results with acceptable accuracy can be obtained by the new model.
  • Keywords
    Thermal Resistance , Similarity , Composite wall , PTRC model
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2008
  • Journal title
    Energy Conversion and Management
  • Record number

    2334131