Title of article
Vector control of autonomous induction generator taking saturation effect into account
Author/Authors
Idjdarene، نويسنده , , K. and Rekioua، نويسنده , , D. and Rekioua، نويسنده , , T. and Tounzi، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
9
From page
2609
To page
2617
Abstract
In this paper, we present the voltage build up process and the terminal voltage control of an isolated wind powered induction generator driven by a variable speed wind turbine using rotor flux oriented vector control. A description of the studied system is provided, and a simulation study is presented. The model used for the autonomous induction generator is a diphase one obtained by application of the Park transform. This model permits, when adopting some simplifying hypotheses, taking account the saturation effect. Wind powered isolated induction generators have an input, wind, that is not controllable, but they can be set to operate within a given variation of speed. Unlike a grid connected induction generator, in an isolated case, there should be a control system that keeps the DC bus voltage at a constant value when the speed of the rotor varies. The paper presents the control system to maintain the DC bus voltage at a constant value. The obtained results are presented and discussed.
Keywords
Saturation , Vector control , Autonomous induction generator
Journal title
Energy Conversion and Management
Serial Year
2008
Journal title
Energy Conversion and Management
Record number
2334143
Link To Document