Title of article
Assembly and performance testing of a MEMS-based μPEMFC with the help of a spiral micrometer
Author/Authors
Zhang، نويسنده , , Xigui and Zhang، نويسنده , , Jian and Wang، نويسنده , , Tao and Zheng، نويسنده , , Dan and Li، نويسنده , , Xinxin and Xia، نويسنده , , Baojia، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
4
From page
3454
To page
3457
Abstract
In this work, a feasible and simple method of assembling a micro MEMS-based μPEMFC (about 0.35 ml in volume and 0.65 g in weight) with the help of a spiral micrometer was proposed. The micrometer provided a constant pressure between the two flow field plates and MEA in assembling for a short term while a special epoxy resin was applied to seal the cell and provide long term pressure between the above components after removing the micrometer. Tests showed that the as-assembled cell had a reasonable performance, which was proved by the linear polarization and EIS experiments. The long term behavior of the μPEMFC was stable in general except for some fluctuation along time. We concluded that this fluctuation was due to a combined effect of heat produced and water management, which the as-assembled μPEMFC has its own ability to adjust. More importantly, this experiment demonstrated the full feasibility and great promise of assembling μFCs with the help of a spiral micrometer.
Keywords
MEMS , Micrometer , Assembling , Air breathing cathode , ?PEMFC
Journal title
Energy Conversion and Management
Serial Year
2008
Journal title
Energy Conversion and Management
Record number
2334342
Link To Document