Title of article :
Instrumentation error analysis of a box-type solar cooker
Author/Authors :
Purohit، نويسنده , , Ishan and Purohit، نويسنده , , Pallav، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
In order to certify the performance of a box-type solar cooker, thermal performance is evaluated in terms of two figures of merit viz. F1 and F2 (IS 13429:2000). The acceptable criterion to make the solar cooker eligible for ISI mark is that the value of F1 should not be less than 0.12, and that of F2 should be greater than 0.40. Further, the solar cooker is classified as Grade A if the value of F1 is determined to be 0.12 or higher; otherwise, the solar cooker is classified as Grade B. Determination of F1 and F2 comprises measurements of the temperature of cooking tray, water temperature and ambient air, solar irradiance, and other associated parameters. The effect of accuracy obtained in these measurements assumes significance in the perspective of grading of solar cookers.
present work, an attempt has been made to analyze the effect of instrumentation on F1 and F2, which is normally employed for testing and standardization of solar cookers. The analysis is supported by a large number of outdoor tests conducted on a box type solar cooker under stagnation as well as load test conditions. It is observed that the variation of absolute value of error in F1 and F2 could be in the range of 0.002–0.003 and 0.015–0.033, respectively. This corresponds to errors of the order of 2.5–3.0% in the evaluation of F1 and 5.0–6.0% in F2.
Keywords :
Box type solar cooker , Stagnation test , Load test , Statistical analysis , Attainable accuracy , Instrumentation error , absolute error
Journal title :
Energy Conversion and Management
Journal title :
Energy Conversion and Management