Title of article :
Development of electrical efficiency measurement techniques for 10 kW-class SOFC system: Part II. Uncertainty estimation
Author/Authors :
Tanaka، نويسنده , , Yohei and Momma، نويسنده , , Akihiko and Kato، نويسنده , , Ken and Negishi، نويسنده , , Akira and Takano، نويسنده , , Kiyonami and Nozaki، نويسنده , , Ken and Kato، نويسنده , , Tohru، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
12
From page :
467
To page :
478
Abstract :
Uncertainty of electrical efficiency measurement was investigated for a 10 kW-class SOFC system using town gas. Uncertainty of heating value measured by the gas chromatography method on a mole base was estimated as ±0.12% at 95% level of confidence. Micro-gas chromatography with/without CH4 quantification may be able to reduce uncertainty of measurement. Calibration and uncertainty estimation methods are proposed for flow-rate measurement of town gas with thermal mass-flow meters or controllers. By adequate calibrations for flowmeters, flow rate of town gas or natural gas at 35 standard litters per minute can be measured within relative uncertainty ±1.0% at 95 % level of confidence. Uncertainty of power measurement can be as low as ±0.14% when a precise wattmeter is used and calibrated properly. It is clarified that electrical efficiency for non-pressurized 10 kW-class SOFC systems can be measured within ±1.0% relative uncertainty at 95% level of confidence with the developed techniques when the SOFC systems are operated relatively stably.
Keywords :
SOFC system , Town gas , Electrical efficiency , uncertainty , Electrical power , Energy input rate
Journal title :
Energy Conversion and Management
Serial Year :
2009
Journal title :
Energy Conversion and Management
Record number :
2334501
Link To Document :
بازگشت