• Title of article

    Concepts of self-acting circulation loops for downward heat transfer (reverse thermosiphons)

  • Author/Authors

    Dobriansky، نويسنده , , Y.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    12
  • From page
    414
  • To page
    425
  • Abstract
    This paper reviews the scientific and technical knowledge related to general self-acting flow loops (thermosiphons and heat pipes) that transmit heat upwards and self-acting reverse flow loops that transmit heat downwards. This paper classifies the heat and mass transfer processes that take place in general flow loops and analyses the nomenclature applied in the literature. It also presents the principles of operation of sixteen reverse flow loops; four of the loops are powered by an external source of energy, while the remaining loops are self-acting. Of the self-acting loops, vapor was used for heat transfer in seven of them and liquid was used in the remaining ones. Based on the available research results, a list of the advantages and disadvantages of both types of loops is presented.
  • Keywords
    Reverse thermosiphons , Loop system powered by local heat , Self-acting downward heat transfer
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2011
  • Journal title
    Energy Conversion and Management
  • Record number