• Title of article

    A new method for early fault detection and diagnosis of broken rotor bars

  • Author/Authors

    Aydin، نويسنده , , Ilhan and Karakose، نويسنده , , Mehmet and Akin، نويسنده , , Erhan، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    10
  • From page
    1790
  • To page
    1799
  • Abstract
    A new method has been developed for the detection and diagnosis of broken rotor bars faults in three-phase induction motors under no-load conditions. Early detection of faults is made by using a sliding window constructed by Hilbert transforms of one of the phases of the thee-phase currents and the size of a fault is diagnosed by motor current signature analysis (MCSA) of the stored Hilbert transforms of several periods of one-phase current. The information entropy of a symbol tree generated by each sliding window is used as a fault index. The method was tested using healthy and damaged 0.37 kW induction motors under no-load conditions with applied voltages ranging from 220 V to 380 V. One and two broken rotor bars were detected under no-load conditions when supply voltages were 260 V and above. The results indicate that the method yields a high degree of accuracy in fault identification.
  • Keywords
    Motor current signature analysis , Fault diagnosis , Sliding window , Hilbert transform , Induction Motors
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2011
  • Journal title
    Energy Conversion and Management
  • Record number

    2335573