Title of article :
The investigations of temperature distributions in an opposed multi-burner gasifier
Author/Authors :
Yu، نويسنده , , Guang-Suo and Yan، نويسنده , , Zhuoyong and Liang، نويسنده , , Qinfeng and Guo، نويسنده , , Qinghua and Zhou، نويسنده , , Zhi-Jie، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Abstract :
In a bench-scale opposed multi-burner (OMB) gasifier, the temperatures of gasification chamber and quench chamber are measured by thermocouples, and the temperature distributions of flame sections are reconstructed by the Filtered back-projection method. The results show that the temperature of gasification chamber increases slowly as the inserted distance increases in both diesel and coal–water slurry (CWS) tests. The syngas temperature decreases rapidly when it passes through the inlet of quench chamber. The impinging flames of diesel or CWS gasification all focus on the gasifier center due to restraining by each other, and can avoid scouring the refractory wall and prolong the lives of refractory. At the test conditions, the temperature distributions of diesel flames are 1650–2100 °C and those of CWS flames are 1500–2000 °C. The flame temperature distributions appear to be a typical simple peak. The investigations can provide some information for the industrial gasifier.
Keywords :
Entrained-flow gasification , Temperature distribution , Flame
Journal title :
Energy Conversion and Management
Journal title :