Title of article :
An experimental study of pressure drop and friction factor for laminar and transition opposing mixed convection in entrance region of rectangular duct
Author/Authors :
Chong، نويسنده , , DaoTong and Liu، نويسنده , , Jiping and Yan، نويسنده , , JunJie، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
10
From page :
2272
To page :
2281
Abstract :
The laminar and transition opposing mixed convection was experimentally investigated when the air flow was in the entrance region through a rectangular duct. The pressure drops were measured under different air flowrates, convective heat fluxes and inclination angles, with the maximum value less than 6.0 Pa. The friction factors were calculated and analyzed under different Reynolds numbers, Grashof numbers and inclination angles. The results indicated that the pressure drops increased with the mean air velocity, and the friction factors showed different characteristics when the Reynolds numbers were larger or smaller than 1500. Finally, the correlations of friction factors were fitted considering the influences of Reynolds number, Grashof number, inclination angle and length to diameter ratio, which fitted the experimental data with the deviations less than ±10.0%.
Keywords :
Mixed convection , Opposing flow , Pressure drop , Friction factor
Journal title :
Energy Conversion and Management
Serial Year :
2011
Journal title :
Energy Conversion and Management
Record number :
2335635
Link To Document :
بازگشت